Features (Manufacturer independant):
- Diagnosis Modules: Stroke, Lesions Comparisons NEW
- Connectomics Analysis (on special Request)
- Functional, Structural and Vascular Neuro-Anatomy : linked to Connectopedia
- fMRI: (Multithread enhanced)
- Real Time / Offline fMRI analysis
- Spatial and temporal pre-processing
(gaussian filtering)
- Paradigm matrix design (first row for
condition number, second row for condition duration) style up to 999
simultaneous conditions using fixed SOA bloc design and HRF convolution.
- Basic statistics for fMRI mapping
(temporal correlation, auto-correlation)
- Multiplanar and 3D surfacic openGl reconstructions,
using all the maps processed in DPTools (diffusion
/ tensor / perfusion / permeability) as well as analyze 16 bits maps.
- 3D ROI settings and basic statistics
(mean, sd, min, max) in Talairach coordinates
- MR Diffusion and Diffusivity: (Multithread
enhanced)
- ADC from Trace DWI images ([b0, bn] or
[b0, bnxx, bnyy, bnzz])
- FA, RA, VA, AI, Ecc,
Cl, Cp, Cs from DTI (6 to 129 directions), or user-defined gradient
sequences.
- Multi-compartimental (intra,
extracellular, ...) modelling of water diffusivity using DWI and DTI MR
Data
- 3D Fibertracking reconstructions
(MedINRIA from Pierre Fillard) for Brain and Spine, with Anatomic and
Functional maps (fMRI, DWI, DTI, PWI, Permeability) Co-registrations
- MR (T2-w, T1-w, ASL) / CT Perfusion and Permeability : (Multithread
enhanced) Patent
WO/2008/132386
- Relative TTP, DR, CBV
- Absolute CBV, CBF, MTT with AIF automated
or semi-automated extraction and deconvolution (FFT or SVD).
- fBV, Kps, k1,
k2, k Tot in T1-w or T2*-w.
- MR Flow:
- Brain Masking and Extraction:
- Brain and cortical (used in 3D surfacic reconstructions) extractions from T1-w
or T2-w MR images
- Co-registration:
- Anatomy / PWI / DTI / Maps / Template (e.g. DWI coregistered on
PWI)
- Volumic Mapping of functional Maps (to
overlay map files to volumic anatomy)
- 3D Multiplanar and MIP Reconstructions,
Volume and Surface Rendering:
- MPR / MIP of series with color mapping
- VOI definitions
- Automated calculation of stroke / tumour volume
- 3D surfacic mapping
and MNI / Talairach atlas
registration
- 3D Tri-linear Interpolation for maps and
diffusion / dynamic series
- Statistics between Series / Maps :
- Mean /
Min / Max / SD
- Z Score
- Chi²
- Pearson Correlation
- Difference
- ROI Histograms :
- Mean / Min / Max / SD, Skewness / Kurtosis
/ Peak Height
- Tensor Fields Statistics :
- Mean /
Min / Max / SD
- Z Score
- Tensor Fields Atlas Template Creation and Statistics :
- Mean /
Min / Max / SD
- Z Score
- Partial Volume Effect Correction:
- Unwarping of MR Series (with Phase
Reference Images)
- ROI:
- Manual drawing or square
- Basic statistics (mean, min, max, sd)
- Filming:
- Film Composer (1 to 16 slices)
- JPEG export
- Loading / Saving:
- ROI, Maps, AIF, Measurements (Text or
Excel)
- DICOM (including Philips DICOM 4) /
ANALYZE / GE / SIEMENS / PHILIPS / RAW
- Siemens MOSAIC acquisition averaging (>VB13)
- Batch Script:
- Diffusion / Dynamic series script procedures to automate processes
- PACS Integration:
- Fully integrated in PACS environment
(Query/Retrieve, Store, Send, Dicomize,
...) up to 6 Dicom nodes as a
standalone application
- Dicom import in DPTools database
from File / CD / ZIP archive / ...
- Database Backup and Restore, Filtering,
...
- Manufacturer Workstations integration:
- Fully automated to work within
professional Review Workstations (succesfully tested
with Merge eFilm, Philips MR Workspace,
Siemens Leonardo, GEMS Advantage Windows using virtualization)
- and more…